MIL-D-52987A(ME)
TABLE I. Examination schedule. Cont'd
First
Requirement
Article
Production
Defect
Paragraph
1
2
3
4
3.5.2
106.
Dissimilar metals as defined in MIL-STD-889
-
X
are not effectively insulated from each other.
3.5.3
107.
Contractor does not have documentations
-
X
available for identification of materials, material
finishes, or treatment.
X
3.5.4
108.
Used, rebuilt or remanufactured components,
-
X
pieces, or parts incorporated in the distributor.
3.6
109.
Safety characteristics not as specified.
X
X
3.6.1
110.
Noise limit or warning plate not as specified.
X
X
3.7.2
111.
Dimensions not as specified.
-
X
3.8
112.
Sectionalization and components not as specified.
X
X
3.10 thru
113.
Tractor section not as specified.
X
X
3.10.10.4
X
3.11
114.
Water tanker section not as specified.
X
3.11.1
115.
Tank, man hole, and vents not as specified.
X
X
thru
3.11.3
3.11.4
116.
Catwalk and ladder not as specified.
X
X
3.11.5
117.
Running gear not as specified.
X
X
3.12
118.
Pump not as specified.
X
X
3.13
119.
Plumping and components not as specified.
X
X
3.14
120.
Water distribution system not as specified.
X
X
3.15
121.
Hydraulic system not as specified.
X
X
3.16
122.
Electrical System not as specified.
X
X
thru
3.16.7
3.17
123.
Antivandalism protection not as specified.
X
X
3.18
124.
Attachments not as specified.
X
X
3.19 thru
125.
Transportability not as specified.
X
X
3.19.8
3.20
126.
Identification plates not as specified.
X
X
3.20.1
127.
Vehicle weight classification numbers not applied as
X
X
specified.
3.20.2
128.
Case not installed as specified.
X
X
3.21
129.
Instruction plates not as specified.
X
X
21
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business